Repository logo
  • English
  • Italiano
Log In
New user? Click here to register.Have you forgotten your password?
Repository logo
  • English
  • Italiano
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ASI Community
  3. SSDC Collection
  4. Planck 2015 results. VIII. High Frequency Instrument data processing Calibration and maps
 
  • Details

Planck 2015 results. VIII. High Frequency Instrument data processing Calibration and maps

Author(s)
Planck Collaboration
Adam, R.
Ade, P. A. R.
Natoli, Paolo  
Polenta, Gianluca  
Subjects

cosmology observation...

cosmic background rad...

surveys

methods data analysis...

Date Issued
2016-08-01
Mission(s)
Planck  
Abstract
This paper describes the processing applied to the cleaned, time-ordered information obtained from the Planck High Frequency Instrument (HFI) with the aim of producing photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5-year HFI mission include almost five full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To obtain the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole, which we call the orbital dipole. This source of calibration only depends on the satellite velocity with respect to the solar system. Using a CMB temperature of T<SUB>CMB</SUB> = 2.7255 0.0006 K, it permits an independent measurement of the amplitude of the CMB solar dipole (3364.3 1.5 muK), which is approximatively 1sigma higher than the WMAP measurement with a direction that is consistent between the two experiments. We describe the pipeline used to produce the maps ofintensity and linear polarization from the HFI timelines, and the scheme used to set the zero level of the maps a posteriori. We also summarize the noise characteristics of the HFI maps in the 2015 Planck data release and present some null tests to assess their quality. Finally, we discuss the major systematic effects and in particular the leakage induced by flux mismatch between the detectors that leads to spurious polarization signal.
URI
https://hdl.handle.net/20.500.13025/4543
DOI
10.1051/0004-6361/201525820
URL
http://adsabs.harvard.edu/abs/2016A&A...594A...8P
Explore by
  • Communities & Collections
  • Research Outputs

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback